AMCC 3WARE 9500S Guia do Utilizador Página 262

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 261
Chapter 12. Troubleshooting
252 3ware Serial ATA RAID Controller User Guide
0040 Flash file system repaired
Event Type
Information
Cause
A corrupted flash file system has been successfully repaired.
Some of the flash files with insufficient data may have been lost in the
operation. The configuration parameters which are lost will then return to
their default values.
Action
We recommend using 3DM, CLI or 3BM to check your settings, in case they
were not able to be restored.
0041 Unit number assignments lost
Event Type
Warning
Cause
The unit number assignments have been lost.
This may have occurred as a result of a soft reset.
Action
Please contact AMCC 3ware technical support at
http://www.3ware.com/
support/index.asp.
0042 Primary DCB read error occurred
Event Type
Warning
Cause
The controller found an error while reading the primary copy of the Disk
Configuration Block (DCB).
The controller will attempt to correct the error by reading the back-up copy of
the DCB. If a valid DCB is found, the primary DCB is re-written to rectify the
errors.
Vista de página 261
1 2 ... 257 258 259 260 261 262 263 264 265 266 267 ... 301 302

Comentários a estes Manuais

Sem comentários