Setting Unit Policies
www.3ware.com 111
The page refreshes, and a message at the top confirms the change you
have made.
To set the Continue on Source Error During Rebuild policy in 3BM
1 At the main 3BM screen, select the unit by highlighting it and pressing
Enter.
An asterisk appears in the left-most column to indicate that it is selected.
2Tab to the
Maintain Unit button and press Enter.
3 On the pop-up menu, select
Configure and press Enter.
4In the
Configure Disk Array screen, Tab to the field Continue on
Source Error During Rebuild
.
5 Press
Enter to display the choices, use the arrow keys to select the
setting you want (Enabled or Disabled), and press
Enter again to choose
it.
6
Tab to the OK button and press Enter to select it.
You return to the main 3BM screen.
7 When you are finished making changes, press
F8 to save them and exit
3BM.
Enabling and Disabling Queuing for a Unit
Some drives support NCQ (Native Command Queuing), a feature that can
result in increased performance for applications that require a lot of random
access of data (usually server-type applications). This is accomplished by
causing command reordering to be done on the drive.
In order to make use of NCQ, the feature must be enabled at both the drive
and the controller. You can enable support for NCQ on a per-unit basis, as
described below.
You can see whether NCQ is supported and enabled for a particular drive in
the Drive Details window. For details, see “Drive Details window” on
page 193.
Note: Not all drives support NCQ. If a drive does not support NCQ, the policy
setting for the controller is ignored.