AMCC 3WARE 9500S Guia do Utilizador Página 17

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 16
Understanding RAID Concepts and Levels
www.3ware.com 7
RAID 5 is able to tolerate 1 drive failure in the unit.
Figure 4. RAID 5 Configuration Example
RAID 6
RAID 6 requires a 3ware 9650SE RAID controller.
RAID 6 provides greater redundancy and fault tolerance than RAID 5. It is
similar to RAID 5, but has two blocks of parity information (P+Q) distributed
across all the drives of a unit, instead of the single block of RAID 5.
Due to the two parities, a RAID 6 unit can tolerate two hard drives failing
simultaneously. This also means that a RAID 6 unit may be in two different
states at the same time. For example, one sub-unit can be degraded, while
another may be rebuilding, or one sub-unit may be initializing, while another
is verifying.
RAID 6 requires a minimum of five drives. Performance and storage
efficiency also increase as the number of drives increase.
Vista de página 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 301 302

Comentários a estes Manuais

Sem comentários