AMCC 3ware 9650SE-2LP Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Controladores RAID AMCC 3ware 9650SE-2LP. LSI 9650SE-2LP-KIT Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - User Guide

3ware® SAS/SATA RAID Software User GuideSupports the 9650SE and 9690SA ModelsPN 720-0184-00 August 2008 User Guide

Página 2 - Disclaimer

x 3ware SAS/SATA RAID Software User Guide, Version 9.5.12. Getting Started Provides a summary of the process you should follow to get started using yo

Página 3 - Table of Contents

Configuring Your Controller88 3ware SAS/SATA RAID Software User Guide, Version 9.5.15 On the pop-up menu, select Controller and press Enter.The Contro

Página 4

About Controller Policieswww.3ware.com 89policies Number of drives per spin-up and Delay between spin-up settings. These policies can only be set usi

Página 5

Configuring Your Controller90 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Viewing Controller PoliciesYou can view the current state of contr

Página 6

Setting the Auto Rebuild Policywww.3ware.com 91To view controller polices in 3BMYou can also view and change these controller polices in 3BM, as show

Página 7

Configuring Your Controller92 3ware SAS/SATA RAID Software User Guide, Version 9.5.1To enable Auto Rebuild through 3DM1 Choose Management > Control

Página 8

Using Auto-Carving for Multi LUN Supportwww.3ware.com 93Each volume can be treated as an individual disk with its own file system. The default carve

Página 9 - About this User Guide

Configuring Your Controller94 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 40. Auto-Carve policy in 3BM2 Create a new unit or migrate

Página 10

Setting the Size of Volumes Created with Auto-Carvingwww.3ware.com 95Setting the Size of Volumes Created with Auto-CarvingYou can use auto-carving to

Página 11 - Screenshots

Configuring Your Controller96 3ware SAS/SATA RAID Software User Guide, Version 9.5.1

Página 12 - Contents

Viewing Information About a Phywww.3ware.com 97If JBOD disks are not exported to the operating system, they will appear as available drives in 3DM, a

Página 13 - SATA RAID Controller

Conventionswww.3ware.com xiConventionsThe following conventions are used throughout this guide:• 3BM refers to the 3ware BIOS Manager.• 3DM and 3DM 2

Página 14 - System Requirements

Configuring Your Controller98 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 41. Phy Summary PageFor details about the columns on this

Página 15 - Drive Requirements

Changing the Phy Link Speedwww.3ware.com 99Changing the Phy Link SpeedYou can change the link speed between the controller and an expander or between

Página 16 - Other Requirements

Configuring Your Controller100 3ware SAS/SATA RAID Software User Guide, Version 9.5.1To change the phy link speed in 3BM 1 On the main 3BM screen, Tab

Página 17 - RAID Concepts

www.3ware.com 1018Configuring UnitsThis section includes information and procedures on configuring units attached to your 3ware RAID controller. It i

Página 18 - Available RAID Configurations

Configuring Units102 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Configuration Options When Creating a UnitThis section provides an overview

Página 19

Configuring a New Unitwww.3ware.com 103Name of the unit (optional)Units can be given names for easier identification. These names will be visible in

Página 20

Configuring Units104 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Multiple VolumesWhen you create a unit through CLI, you have the option of

Página 21

Configuring a New Unitwww.3ware.com 105Creating a Unit through 3DMIn 3DM, creating a unit starts from the Management > Maintenance page (Figure 45

Página 22

Configuring Units106 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 46. Configuring a Unit in 3DM4In the Type field, select the RAID co

Página 23 - Hot Spare

Configuring a New Unitwww.3ware.com 1079 Click OK.The new unit appears in the Unit Maintenance list at the top of the page and the operating system i

Página 24

xii 3ware SAS/SATA RAID Software User Guide, Version 9.5.1To make use of the 3ware HTML Bookshelf1 To launch the bookshelf at the opening page, do one

Página 25

Configuring Units108 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 49. Asterisks Next to Selected Drives 2 After all drives for the un

Página 26 - Support for Over 2 Terabytes

Configuring a New Unitwww.3ware.com 1095 Tab to the RAID Configuration field and press Enter to display a list of available configurations for the nu

Página 27 - Management

Configuring Units110 3ware SAS/SATA RAID Software User Guide, Version 9.5.1You are returned to the main 3BM screen.12 When you are finished making con

Página 28 - Troubleshooting Features

Configuring a New Unitwww.3ware.com 111Ordering Units in 3BMIf you configure multiple units in 3BM and you want to install the OS on one of them so t

Página 29

Configuring Units112 3ware SAS/SATA RAID Software User Guide, Version 9.5.16 Follow the steps that appear on-screen to create a volume and to assign a

Página 30 - 3ware RAID Controller

Creating a Hot Sparewww.3ware.com 113Use of the -j option to turn on journaling is recommended for large partitions. For example:mkfs -j /dev/sda1 If

Página 31

Configuring Units114 3ware SAS/SATA RAID Software User Guide, Version 9.5.1In order to replace a failed drive, a hot spare must have the same or large

Página 32

Naming a Unitwww.3ware.com 115Specifying a Hot Spare through 3BM1 On the main 3BM screen, in the list of Available Drives, highlight the drive you wa

Página 33

Configuring Units116 3ware SAS/SATA RAID Software User Guide, Version 9.5.14 In the text box, enter or type over the name shown. A name can be up to 2

Página 34 - Using 3BM

Setting Unit Policieswww.3ware.com 117• Auto Verify. Determines whether the unit will be automatically verified at a time determined by the Verify Sc

Página 35 - Figure 8. 3ware BIOS Screen

www.3ware.com 11Introducing the 3ware® SAS/SATA RAID ControllerAMCC 3ware RAID controllers deliver full-featured, true hardware RAID to servers and w

Página 36

Configuring Units118 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 55. Unit Policies on Controller Settings Page in 3DM

Página 37

Setting Unit Policieswww.3ware.com 119If you have a BBU (Battery Backup Unit) installed on the controller, the battery preserves the contents of the

Página 38

Configuring Units120 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 56. Unit Write Cache State in 3BM The current setting—Enabled or Di

Página 39

Setting Unit Policieswww.3ware.com 121To enable or disable the Auto Verify policy for an existing unit through 3DM1 Choose Management > Controller

Página 40

Configuring Units122 3ware SAS/SATA RAID Software User Guide, Version 9.5.1To set the Overwrite ECC policy in 3DM1 Choose Management > Controller S

Página 41

Setting Unit Policieswww.3ware.com 123 To enable or disable queuing for a unit through 3DM1 Choose Management &g

Página 42 - Specifying a Hot Spare

Configuring Units124 3ware SAS/SATA RAID Software User Guide, Version 9.5.1About StorSave Profile LevelsThe three profiles automatically adjust severa

Página 43 - What Next?

Setting Unit Policieswww.3ware.com 125Using write journaling helps protect your data, however it can have an impact on performance. The Protection pr

Página 44 - Driver Installation

Configuring Units126 3ware SAS/SATA RAID Software User Guide, Version 9.5.15 Press Enter to display the choices, use the arrow keys to select the sett

Página 45 - Materials Required

Setting Unit Policieswww.3ware.com 127• Units with Rapid RAID Recovery enabled will not be readable if moved to controllers using pre-9.5.1 firmware.

Página 46 - AutoPlay

Introducing the 3ware® SAS/SATA RAID Controller2 3ware SAS/SATA RAID Software User Guide, Version 9.5.1• Support for the I2C-MUX-SM1 on the 9690SA• 8t

Página 47

Configuring Units128 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Changing An Existing Configuration by MigratingYou can convert one RAID con

Página 48 - Install Windows Drivers

Changing An Existing Configuration by Migratingwww.3ware.com 129Figure 57. RAID Level Migration Example Typical

Página 49 - 3 Click Next

Configuring Units130 3ware SAS/SATA RAID Software User Guide, Version 9.5.1

Página 50 - Found New Hardware wizard

Changing An Existing Configuration by Migratingwww.3ware.com 1314 Select any drives to be added to the unit.5 Select the new RAID level. 6 Optionally

Página 51

Configuring Units132 3ware SAS/SATA RAID Software User Guide, Version 9.5.17 If you booted from the unit that is being migrated, when migration is com

Página 52

Deleting a Unitwww.3ware.com 133• Go to Administrative Tools > Computer Management, and then select Disk Management in the list on the left.Only d

Página 53 - Available to Windows

Configuring Units134 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Deleting a Unit through 3DMIn 3DM, the command for deleting a unit is on th

Página 54

Deleting a Unitwww.3ware.com 135Figure 58. Unit Successfully Deleted through 3DM Deleting a Unit through 3BMIn 3BM, the command for deleting a unit

Página 55 - Obtaining 3ware Linux Drivers

Configuring Units136 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 59. Deleting a Unit in 3BM4 Tab to the OK button and press Enter.Yo

Página 56 - Materials required

Removing a Unitwww.3ware.com 137Removing a Unit Through 3DMIn 3DM, the command for deleting a unit is on the Maintenance page. Be sure to follow step

Página 57

System Requirementswww.3ware.com 3 Drive Requirements For 9650SE Model ControllersDepending on the particular mo

Página 58 - Instructions

Configuring Units138 3ware SAS/SATA RAID Software User Guide, Version 9.5.1If you change your mind before physically removing the drives and want to r

Página 59

Moving a Unit from One Controller to Anotherwww.3ware.com 1393DM includes two features that help you move a unit without powering down the system, al

Página 60

Configuring Units140 3ware SAS/SATA RAID Software User Guide, Version 9.5.12 Update the driver for the 9650SE or 9690SA RAID controller. If you are us

Página 61

Moving a Unit from One Controller to Anotherwww.3ware.com 141Moving Units from an 8000 Controller to a 9000 ControllerIt is possible to move your RAI

Página 62

Configuring Units142 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Moving Legacy JBOD Units to a 9000 ControllerThe steps for moving legacy JB

Página 63

Removing a Drivewww.3ware.com 143 To add a drive1 Insert the drive into the hot swap bay or into your enclosure.

Página 64

Configuring Units144 3ware SAS/SATA RAID Software User Guide, Version 9.5.1To remove a drive1 In 3DM, choose Management > Maintenance. On the Maint

Página 65

Rescanning the Controllerwww.3ware.com 145Rescanning the ControllerWhen you make a change by physically adding or removing drives or units, you can h

Página 66

www.3ware.com 1469Maintaining Units3ware RAID controllers include a number of features in the firmware that help maintain the integrity of your drive

Página 67

Checking Unit and Drive Status through 3DMwww.3ware.com 147The next figure illustrates how you can drill down to get additional detail about units an

Página 68

Introducing the 3ware® SAS/SATA RAID Controller4 3ware SAS/SATA RAID Software User Guide, Version 9.5.1A list of drives that have been tested is avail

Página 69

Maintaining Units148 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Viewing a List of DrivesYou can see a list of drives connected to your 3war

Página 70

Checking Unit and Drive Status through 3DMwww.3ware.com 149Tip: You can scroll both sections of the Drive Information page to bring additional drive

Página 71

Maintaining Units150 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Unit StatusesThe following is a list of unit statuses you may see in 3DM:•O

Página 72 - Introduction

About Degraded Unitswww.3ware.com 151• Migrate-Paused. The unit is in the process of migrating, however scheduling is enabled, and the present time i

Página 73

Maintaining Units152 3ware SAS/SATA RAID Software User Guide, Version 9.5.1You can still read and write data from a degraded unit, but the unit will n

Página 74 - F8 or Esc key

Locating a Drive by Blinking Its LEDwww.3ware.com 153• Choose Monitor > Enclosure from the main menu in 3DM. On the list of enclosures, click the

Página 75 - Working in the 3BM Screens

Maintaining Units154 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Alarms, Errors, and Other Events3ware provides several levels of detail abo

Página 76

Alarms, Errors, and Other Eventswww.3ware.com 155If your 3ware RAID controller is installed in a Windows system, the WinAVAlarm alert utility can not

Página 77 - Table 7: Working in 3BM

Maintaining Units156 3ware SAS/SATA RAID Software User Guide, Version 9.5.1To change the alert utility settings1 Double-click on the WinAVAlarm icon i

Página 78

Alarms, Errors, and Other Eventswww.3ware.com 157Downloading an Error LogYou can download an error log containing information from the firmware log.

Página 79 - Changing BIOS Settings

Understanding RAID Concepts and Levelswww.3ware.com 5In addition:• JavaScript must be enabled• Cookies must be enabled• For best viewing, screen reso

Página 80

Maintaining Units158 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Background TasksBackground tasks are maintenance tasks that help maintain t

Página 81 - Getting Help While Using 3BM

Background Taskswww.3ware.com 159Some RAID levels must be initialized for best performance. (For specifics, see “Initialization of Different RAID Typ

Página 82 - 3DM 2 (3ware Disk Manager)

Maintaining Units160 3ware SAS/SATA RAID Software User Guide, Version 9.5.1 Initialization of Different RAID Type

Página 83 - Setting up Mozilla Firefox

Background Taskswww.3ware.com 161 Initialization of RAID 1 and RAID 10 UnitsRAID 1 and RAID 10 units do not need

Página 84 - Starting 3DM and Logging In

Maintaining Units162 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Background Initialization After Power FailureThe 3ware controller detects a

Página 85

Background Taskswww.3ware.com 163 What Verification DoesFor a RAID 1 or RAID 10 unit, a verify compares the data

Página 86

Maintaining Units164 3ware SAS/SATA RAID Software User Guide, Version 9.5.1For RAID 1 and 10, verification involves copying the data from the lower po

Página 87 - Working with the 3DM Screens

Background Taskswww.3ware.com 165For users who need more control over when Verify tasks run, an Advanced Verify schedule is also available, which giv

Página 88 - 3DM Menus

Maintaining Units166 3ware SAS/SATA RAID Software User Guide, Version 9.5.1To verify a unit through 3DM1 In 3DM, choose Management > Maintenance.2I

Página 89

Background Taskswww.3ware.com 167 Rebuilding UnitsRebuilding is the process of generating data on a new drive af

Página 90 - Refreshing the Screen

Introducing the 3ware® SAS/SATA RAID Controller6 3ware SAS/SATA RAID Software User Guide, Version 9.5.1• Distributed Parity. Parity works in combinati

Página 91

Maintaining Units168 3ware SAS/SATA RAID Software User Guide, Version 9.5.1A RAID 50 unit can sustain multiple drive failures, as long there is only o

Página 92 - Table 8: List of 3DM Pages

Background Taskswww.3ware.com 169If rebuild scheduling is not enabled on the Scheduling page, the rebuild process begins almost immediately in the ba

Página 93 - Setting Up 3DM Preferences

Maintaining Units170 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 69. Degraded Disk Array Warning Message2 Press a key to continue.3

Página 94

Background Taskswww.3ware.com 171Figure 70. Rebuild Option on the Maintain Menu The Rebuild Disk Array screen displays.Figure 71. Rebuild Disk Arra

Página 95 - Notification

Maintaining Units172 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Cancelling a Rebuild and Restarting It with a Different DriveWhen you start

Página 96 - Setting the Listening Port #

Scheduling Background Taskswww.3ware.com 173Background Task PrioritizationAlthough migration tasks follow the same schedule as rebuild and initializa

Página 97

Maintaining Units174 3ware SAS/SATA RAID Software User Guide, Version 9.5.1 You can also set the rate at which ba

Página 98

Scheduling Background Taskswww.3ware.com 175Figure 72. Selecting Task Schedules to ViewTurning On or Off Use of a Rebuild/Migrate Task ScheduleTurni

Página 99

Maintaining Units176 3ware SAS/SATA RAID Software User Guide, Version 9.5.12 In the Schedule Rebuild Tasks section, select the appropriate setting: Fo

Página 100 - About Controller Policies

Scheduling Background Taskswww.3ware.com 177To remove a task slot from a schedule1 Choose Management > Schedule from the menu bar.The Scheduling p

Página 101

Understanding RAID Concepts and Levelswww.3ware.com 7Figure 2. RAID 0 Configuration Example RAID 1RAID 1 provid

Página 102 - Viewing Controller Policies

Maintaining Units178 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Selecting Self-tests to be PerformedFor 3ware RAID controllers older than t

Página 103

179 3ware SAS/SATA RAID Software User Guide, Version 9.5.110Maintaining Your ControllerThis section contains instructions for how to perform tasks tha

Página 104

Maintaining Your Controller180 3ware SAS/SATA RAID Software User Guide, Version 9.5.1If you have a 2.6 kernel without sysfs, type the following comman

Página 105

Updating the Firmware and Driverwww.3ware.com 181• Windows users can also update the driver through Windows Device Manager. For details, see “Updatin

Página 106 - Configuring Your Controller

Maintaining Your Controller182 3ware SAS/SATA RAID Software User Guide, Version 9.5.16 Click Next.7 When details about the download you requested appe

Página 107 - Auto-Carving

Updating the Firmware and Driverwww.3ware.com 1833In the Update Firmware section of Controller Settings page, browse to the location where you have s

Página 108 - Exporting JBOD Disks

Maintaining Your Controller184 3ware SAS/SATA RAID Software User Guide, Version 9.5.16 To continue, type:yThe program checks that the update program v

Página 109

Updating the Firmware and Driverwww.3ware.com 185Figure 73. Update Utility Progress Dialog (System Check)When the 3ware Driver/Firmware Update dialo

Página 110

Maintaining Your Controller186 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 75. Update Utility Showing Drivers Already Current.If the

Página 111 - Changing the Phy Link Speed

Updating the Firmware and Driverwww.3ware.com 187Figure 77. Update Utility Showing Only Firmware Available 6 In

Página 112

Copyright ©2004-2008 Applied Micro Circuits Corporation (AMCC). All rights reserved. This publication may be copied or reproduced for reference purpos

Página 113 - Configuring Units

Introducing the 3ware® SAS/SATA RAID Controller8 3ware SAS/SATA RAID Software User Guide, Version 9.5.1RAID 5 is able to tolerate 1 drive failure in t

Página 114

Maintaining Your Controller188 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 78. Dialog Prompting for Restart8 If the driver you are i

Página 115 - Boot volume size

Updating the Firmware and Driverwww.3ware.com 189When the 3ware Driver/Firmware Update dialog box appears, it lists the number of controllers in your

Página 116 - Unit policies

Maintaining Your Controller190 3ware SAS/SATA RAID Software User Guide, Version 9.5.12 Backup any critical data prior to updating the 3ware driver.3 L

Página 117 - Creating a Unit through 3DM

Updating the Firmware and Driverwww.3ware.com 191Select “No, not this time” and click Next.Figure 82. Windows XP Service Pack 2 Windows Update Query

Página 118

Maintaining Your Controller192 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 84. Search for Driver Screen14 When the Select the Device

Página 119 - Creating a Unit through 3BM

Updating the Firmware and Driverwww.3ware.com 193Figure 86. Install From Disk Dialog Box16 When the Select the Device Driver dialog box reappears, s

Página 120

Maintaining Your Controller194 3ware SAS/SATA RAID Software User Guide, Version 9.5.119 If you are prompted to restart the system, do so. Shortly afte

Página 121

Updating the Firmware and Driverwww.3ware.com 19521 When the second Completing the Found New Hardware screen appears, click Finish.Figure 89. Comple

Página 122

Maintaining Your Controller196 3ware SAS/SATA RAID Software User Guide, Version 9.5.14 Copy the files to the appropriate directory. (In the commands b

Página 123 - Ordering Units in 3BM

Updating the Firmware and Driverwww.3ware.com 197For Red Hat Hugememmkinitrd –v –f initrd-<kernel string>hugmem.img <kernel string>hugmem

Página 124

Understanding RAID Concepts and Levelswww.3ware.com 9Figure 5. RAID 6 Configuration Example RAID 10RAID 10 is a

Página 125 - Creating a Hot Spare

Maintaining Your Controller198 3ware SAS/SATA RAID Software User Guide, Version 9.5.15Run /sbin/depmod -a6 Make sure the file /lib/modules/<kernel

Página 126

Updating the Firmware and Driverwww.3ware.com 199Updating 3ware Drivers under FreeBSDDrivers can be updated either from source files or with driver m

Página 127 - Naming a Unit

Maintaining Your Controller200 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Updating the 3ware Kernel Driver Module Under FreeBSDThe followin

Página 128 - Setting Unit Policies

Updating the Firmware and Driverwww.3ware.com 201To compile the driver as a module1 Boot to FreeBSD.2 Download and extract the driver, as described u

Página 129

Maintaining Your Controller202 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Updating 3ware Drivers under VMwareDriver updates for the 3ware R

Página 130

Testing Battery Capacitywww.3ware.com 203 To view information about a BBU in 3DM 2• On the menu bar, choose Moni

Página 131

Maintaining Your Controller204 3ware SAS/SATA RAID Software User Guide, Version 9.5.1To test the battery in a BBU in 3DM 21 On the menu bar, choose Mo

Página 132

Testing Battery Capacitywww.3ware.com 205To test the battery in a BBU in 3BM1 At the main 3BM screen, tab to the BBU button and press Enter.2Tab to T

Página 133 - When Rebuilding)

www.3ware.com 20611Managing an Enclosure3ware enclosure management features let you view the status of enclosure hardware, such as fans, power suppli

Página 134

Viewing a List of Enclosureswww.3ware.com 207Viewing a List of EnclosuresIf you have multiple enclosures attached to your 3ware RAID controller, you

Página 135

Introducing the 3ware® SAS/SATA RAID Controller10 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 6. RAID 10 Configuration Example

Página 136 - About StorSave Profile Levels

Managing an Enclosure208 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 94. Enclosure Information page (3BM)Checking Enclosure Componen

Página 137

Checking Enclosure Component Statuswww.3ware.com 209Figure 95. Enclosure Details page To check the status of co

Página 138 - Rapid RAID Recovery

Managing an Enclosure210 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Temp Sensor StatusBelow is a list of possible temperature sensor status

Página 139

Locating a Specific Enclosure Componentwww.3ware.com 211Locating a Specific Enclosure ComponentIf you have a supported enclosure and the identify fea

Página 140 - Migrating

212 3ware SAS/SATA RAID Software User Guide, Version 9.5.1123DM 2 ReferenceThis section includes details about the fields and features available on th

Página 141

Controller Summary pagewww.3ware.com 213Controller Summary pageFigure 96. Controller Summary Page The Summary p

Página 142 - Changing RAID Level

3DM 2 Reference214 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Controller Details pageFigure 97. Controller Details Page

Página 143 - Expanding Unit Capacity

Unit Information pagewww.3ware.com 215Bus Width. The bus width detected by the controller. This is 8 lanes for the 9690SA controller. It may be 1, 4,

Página 144 - Configuration

3DM 2 Reference216 3ware SAS/SATA RAID Software User Guide, Version 9.5.1To see details about a particular unit, click the link in the Unit # column.

Página 145 - Deleting a Unit

Unit Details pagewww.3ware.com 217Unit Details pageFigure 99. Unit Details Page The Unit Details page appears w

Página 146 - Deleting a Unit through 3DM

Understanding RAID Concepts and Levelswww.3ware.com 11Figure 7. RAID 50 Configuration Example Single DiskA sing

Página 147 - Deleting a Unit through 3BM

3DM 2 Reference218 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Serial #. The serial number of the unit. This number is assigned by the firmw

Página 148 - Removing a Unit

Drive Information pagewww.3ware.com 219Drive Information pageFigure 100. Drive Information Page The Drive Infor

Página 149 - Removing a Unit Through 3DM

3DM 2 Reference220 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Capacity. The physical capacity of the drive. (Note that the capacity as show

Página 150 - Removing a Unit Through 3BM

Drive Details windowwww.3ware.com 221Drive Details windowFigure 101. Drive Details Page The Drive Details windo

Página 151 - 9650SE or 9690SA Controller

3DM 2 Reference222 3ware SAS/SATA RAID Software User Guide, Version 9.5.1SAS WWN. The SAS drive’s unique World Wide Number.Reallocated Sectors. The nu

Página 152

Controller Phy Summary pagewww.3ware.com 223Controller Phy Summary pageFigure 102. Controller Phy Summary Page

Página 153 - Controller

3DM 2 Reference224 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Controller Settings pageFigure 103. Controller Settings Page

Página 154 - Adding a Drive

Controller Settings pagewww.3ware.com 225Background Task RateThe Background Task Rate fields let you change the balance of background tasks and I/O (

Página 155 - Removing a Drive

3DM 2 Reference226 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Drive and choosing Properties; then on the Tools tab, click Check Now. Under

Página 156

Controller Settings pagewww.3ware.com 227Other Controller SettingsThe Other Controller settings displays information about additional settings, some

Página 157 - Rescanning the Controller

Introducing the 3ware® SAS/SATA RAID Controller12 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Determining What RAID Level to UseYour choice

Página 158 - Maintaining Units

3DM 2 Reference228 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Update FirmwareThe Update Firmware function allows you to update the firmware

Página 159

Scheduling pagewww.3ware.com 2293DM then updates the page to show you schedule details for that type of task. Sc

Página 160 - Viewing a List of Drives

3DM 2 Reference230 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Self-test SchedulesUnlike scheduling of rebuilds and verifies, scheduling of

Página 161

Maintenance pagewww.3ware.com 231Maintenance pageFigure 105. Maintenance Page The Maintenance page appe

Página 162 - Unit Statuses

3DM 2 Reference232 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Rescanning is useful in a variety of maintenance tasks. For example, if you p

Página 163 - Drive Statuses

Maintenance pagewww.3ware.com 233Unit Number. The unit number assigned to the unit by the firmware. Use the checkbox next to the unit to select a uni

Página 164 - About Inoperable Units

3DM 2 Reference234 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Maintenance Task ButtonsBelow the list of units, a row of task buttons lets y

Página 165

Maintenance pagewww.3ware.com 235rebuilding.) If rebuild scheduling is not enabled, the rebuild process will begin right away.For more information ab

Página 166

3DM 2 Reference236 3ware SAS/SATA RAID Software User Guide, Version 9.5.1 When you click Remove Unit, you will be

Página 167 - Monitor > Alarms

Maintenance pagewww.3ware.com 237 After deletion, the operating system is notified that the unit was deleted. In

Página 168

Understanding RAID Concepts and Levelswww.3ware.com 13Using Drive Capacity EfficientlyTo make the most efficient use of drive capacity, it is advisab

Página 169 - Downloading an Error Log

3DM 2 Reference238 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 107. Configuration Window in 3DM

Página 170 - About Initialization

Maintenance pagewww.3ware.com 239will give better performance with applications that have a lot of random reads and writes. In general, the smaller t

Página 171 - Background Tasks

3DM 2 Reference240 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Alarms pageFigure 109. Alarms Page The

Página 172

Battery Backup pagewww.3ware.com 241Battery Backup pageFigure 110. Battery Backup Page The Battery Backup page

Página 173

3DM 2 Reference242 3ware SAS/SATA RAID Software User Guide, Version 9.5.1If the battery is ever discharged through a backup cycle or if the system pow

Página 174 - About Verification

Enclosure Summary pagewww.3ware.com 243Enclosure Summary pageFigure 111. Enclosure Summary Page The Enclosure

Página 175 - What Verification Does

3DM 2 Reference244 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Enclosure Details pageFigure 112. Enclosure Details Page

Página 176 - Using Auto Verification

Enclosure Details pagewww.3ware.com 245Enclosure IDStatus. The status of the enclosure.Vendor. The manufacturer of the enclosure.Product ID. The prod

Página 177 - Starting a Verify Manually

3DM 2 Reference246 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Power Supply SummaryPower Supply. The ID number associated with the specified

Página 178

3DM 2 Settings pagewww.3ware.com 2473DM 2 Settings pageFigure 113. 3DM 2 Settings Page The 3DM 2 Settings page

Página 179 - Rebuilding Units

Introducing the 3ware® SAS/SATA RAID Controller14 3ware SAS/SATA RAID Software User Guide, Version 9.5.1down to 120 GB. For more information, see the

Página 180 - Rebuilding a Unit Through 3DM

3DM 2 Reference248 3ware SAS/SATA RAID Software User Guide, Version 9.5.1• Remote Access• HTTP SettingsE-mail NotificationUse the fields in this secti

Página 181 - Rebuilding Units through 3BM

3DM 2 Settings pagewww.3ware.com 249Confirm New Password. Enter the new password a second time, to be sure you have entered it correctly. Change Pass

Página 182

250 3ware SAS/SATA RAID Software User Guide, Version 9.5.113TroubleshootingThis troubleshooting section includes the following sections:• Web Resource

Página 183

Before Contacting Customer Supportwww.3ware.com 251Before Contacting Customer SupportFour screens in 3DM 2 provide controller version and status info

Página 184 - Setting Background Task Rate

Troubleshooting252 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Command LoggingAll changes that are made to RAID configurations using 3DM or

Página 185 - Scheduling Background Tasks

Drive Performance Monitoringwww.3ware.com 253Drive Performance MonitoringWhen one drive in a RAID unit is responding much slower than others, it redu

Página 186 - Scheduled Task Duration

Troubleshooting254 3ware SAS/SATA RAID Software User Guide, Version 9.5.1• Display a DPM Summary. This shows whether DPM is On or Off, and provides su

Página 187 - Schedule

Problems and Solutionswww.3ware.com 255Problems and SolutionsThis section covers some common problems and solutions. It is organized into the followi

Página 188

Troubleshooting256 3ware SAS/SATA RAID Software User Guide, Version 9.5.1• The motherboard may be functional, but may not be compatible. Please check

Página 189 - Wednesday (slot-1)

Problems and Solutionswww.3ware.com 257A unit shows up as unusable, because of missing drives: Unusable Arrays: 3 drive 64K RAID 5 558.77 GB (Unit

Página 190 - Tasks column

3ware Tools for Configuration and Managementwww.3ware.com 153ware Tools for Configuration and Management3ware software tools let you easily configure

Página 191 - Maintaining Your Controller

Troubleshooting258 3ware SAS/SATA RAID Software User Guide, Version 9.5.1If a drive that previously showed up in 3DM or 3BM does not show up, try the

Página 192

Error and Notification Messageswww.3ware.com 259 Table 13: Error and Notification Message ListValue Message0001

Página 193 - Download Released Software

Troubleshooting260 3ware SAS/SATA RAID Software User Guide, Version 9.5.10028 DCB version unsupported0029 Verify started002A Verify failed002B Verify

Página 194

Error and Notification Messageswww.3ware.com 2610047 Battery voltage is too low0048 Battery voltage is too high0049 Battery temperature is normal004A

Página 195 - 3ware Bootable CD

Troubleshooting262 3ware SAS/SATA RAID Software User Guide, Version 9.5.18002 Enclosure fan removed8003 Enclosure fan added8004 Enclosure fan unknown8

Página 196 - Under Windows

Error and Notification Messageswww.3ware.com 2638004 Enclosure fan unknown8005 Enclosure fan off8020 Enclosure temp normal8021 Enclosure temp low8022

Página 197

Troubleshooting264 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Error and Notification Message Details0001 Controller reset occurredEvent Typ

Página 198

Error and Notification Messageswww.3ware.com 265See Also“About Degraded Units” on page 151“Rebuilding Units” on page 1670003 Controller error occurre

Página 199 - Only the firmware is

Troubleshooting266 3ware SAS/SATA RAID Software User Guide, Version 9.5.1To lower the likelihood of getting this error, schedule regular verifications

Página 200

Error and Notification Messageswww.3ware.com 2670007 Initialize completedEvent TypeInformationCauseThe 3ware RAID controller completed the “synching”

Página 201

Introducing the 3ware® SAS/SATA RAID Controller16 3ware SAS/SATA RAID Software User Guide, Version 9.5.1• 3ware CLI (Command Line Interface)The 3ware

Página 202

Troubleshooting268 3ware SAS/SATA RAID Software User Guide, Version 9.5.10009 Drive timeout detectedEvent TypeErrorCauseA drive has failed to respond

Página 203

Error and Notification Messageswww.3ware.com 269ActionIf you see this message, the drive repairs may lie outside of the 3ware RAID controller’s abili

Página 204 - Have Disk… button

Troubleshooting270 3ware SAS/SATA RAID Software User Guide, Version 9.5.1ActionAllow the initialization to complete. This will return the unit to its

Página 205

Error and Notification Messageswww.3ware.com 271as error rates and retry counts.This type of monitoring may be able to predict a drive failure before

Página 206

Troubleshooting272 3ware SAS/SATA RAID Software User Guide, Version 9.5.1ActionThe drive is now available for use. If the drive is part of a unit add

Página 207 - Fedora Core

Error and Notification Messageswww.3ware.com 273CauseDrive insertion caused a unit that was inoperable to become operational again. Any data that was

Página 208

Troubleshooting274 3ware SAS/SATA RAID Software User Guide, Version 9.5.10022 Upgrade UDMA modeEvent TypeWarningCauseDuring a self-test, the controlle

Página 209

Error and Notification Messageswww.3ware.com 2750024 Buffer integrity test failedEvent TypeError.CauseThe 3ware RAID controller performs diagnostics

Página 210

Troubleshooting276 3ware SAS/SATA RAID Software User Guide, Version 9.5.10026 Drive ECC error reportedEvent TypeErrorCauseDrive ECC errors are an indi

Página 211

Error and Notification Messageswww.3ware.com 277ActionIf this error occurs, please contact 3ware technical support at http://www.3ware.com/support/in

Página 212

Monitoring, Maintenance, and Troubleshooting Featureswww.3ware.com 17• Verification and Media Scans. The verify task verifies all redundant units, an

Página 213

Troubleshooting278 3ware SAS/SATA RAID Software User Guide, Version 9.5.1See AlsoFor information on scheduling a verify process, see “Scheduling Backg

Página 214 - Viewing Battery Information

Error and Notification Messageswww.3ware.com 279place during off-hours. For more information, see “Scheduling Background Tasks” on page 166. You can

Página 215 - Testing Battery Capacity

Troubleshooting280 3ware SAS/SATA RAID Software User Guide, Version 9.5.1002D Source drive error occurredEvent TypeErrorCauseAn error on the source dr

Página 216

Error and Notification Messageswww.3ware.com 281ActionUse a replacement drive equal to or larger than the drives already in use 002F Verify not start

Página 217

Troubleshooting282 3ware SAS/SATA RAID Software User Guide, Version 9.5.1See AlsoFor a list of compatible drives, see http://www.3ware.com/products/co

Página 218 - Managing an Enclosure

Error and Notification Messageswww.3ware.com 283CauseThe migration of a unit has failed.Migration changes can include:• Expanding capacity of a unit

Página 219 - Viewing a List of Enclosures

Troubleshooting284 3ware SAS/SATA RAID Software User Guide, Version 9.5.10036 Verify fixed data/parity mismatchEvent TypeWarningCauseA verify error wa

Página 220

Error and Notification Messageswww.3ware.com 285CauseThe 3ware 9500S RAID controller is inoperable due to missing SO-DIMM memory.Note: This message o

Página 221 - Fan Status

Troubleshooting286 3ware SAS/SATA RAID Software User Guide, Version 9.5.1ActionIf this drive was the only one to lose power, check the cable connectio

Página 222 - Slot Summary

Error and Notification Messageswww.3ware.com 287See Also“Viewing Current Task Schedules” on page 174“About Initialization” on page 158003D Verify pau

Página 223

www.3ware.com iiiTable of ContentsAbout this User Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix How this

Página 224 - 3DM 2 Reference

www.3ware.com 182Getting Started with Your 3ware RAID ControllerSetting up your 3ware RAID controller involves these main steps:• Physically Install

Página 225 - Controller Summary page

Troubleshooting288 3ware SAS/SATA RAID Software User Guide, Version 9.5.1“Scheduling Background Tasks” on page 173003F Flash file system error detecte

Página 226 - Controller Details page

Error and Notification Messageswww.3ware.com 2890041 Unit number assignments lostEvent TypeWarningCauseThe unit number assignments have been lost.Thi

Página 227 - Unit Information page

Troubleshooting290 3ware SAS/SATA RAID Software User Guide, Version 9.5.1The 3ware RAID controller checks the backup DCB, even when the primary DCB is

Página 228

Error and Notification Messageswww.3ware.com 291CauseThe battery pack voltage being monitored by the Battery Backup Unit has risen above the warning

Página 229 - Unit Details page

Troubleshooting292 3ware SAS/SATA RAID Software User Guide, Version 9.5.12 Remove the BBU control module from the 3ware RAID controller and the batter

Página 230

Error and Notification Messageswww.3ware.com 293004B Battery temperature is highEvent TypeErrorCauseThe battery pack temperature being monitored by t

Página 231 - Drive Information page

Troubleshooting294 3ware SAS/SATA RAID Software User Guide, Version 9.5.1004D Battery temperature is too highEvent TypeErrorCauseThe battery pack temp

Página 232

Error and Notification Messageswww.3ware.com 295See AlsoSee the Install Guide for your controller.004F Cache synchronization skippedEvent TypeWarning

Página 233 - Extra Drive Information

Troubleshooting296 3ware SAS/SATA RAID Software User Guide, Version 9.5.10052 Battery health check completedEvent TypeInformationCauseThe Battery Back

Página 234 - SMART Data

Error and Notification Messageswww.3ware.com 2970056 Battery charging completedEvent TypeInformationCauseThe Battery Backup Unit has completed a batt

Página 235 - Controller Phy Summary page

www.3ware.com 19installation in. Chapter 3, “First-Time RAID Configuration Using 3BM.” Additional information about configuration is also included in

Página 236 - Controller Settings page

Troubleshooting298 3ware SAS/SATA RAID Software User Guide, Version 9.5.10059 Battery capacity is below error levelEvent TypeErrorCauseThe measured ca

Página 237 - Unit Policies

Error and Notification Messageswww.3ware.com 299005C Battery is weakEvent TypeWarningCauseThe Battery Backup Unit periodically evaluates the health o

Página 238 - Unit Names

Troubleshooting300 3ware SAS/SATA RAID Software User Guide, Version 9.5.1You will also see this message if drive insertion causes a unit to become ope

Página 239 - Other Controller Settings

Error and Notification Messageswww.3ware.com 3010064 Local link upEvent TypeInformation.CauseApplies only to the 9690SA controller.A cable has been p

Página 240 - Scheduling page

Troubleshooting302 3ware SAS/SATA RAID Software User Guide, Version 9.5.1The enclosure fan is not functioning normally and may be blocked or defective

Página 241 - Task Schedules

Error and Notification Messageswww.3ware.com 303CauseApplies only to the 9690SA controller.The enclosure is unable to recognize the fan. The fan may

Página 242 - Self-test Schedules

Troubleshooting304 3ware SAS/SATA RAID Software User Guide, Version 9.5.18021 Enclosure temp lowEvent TypeInformation.CauseApplies only to the 9690SA

Página 243 - Maintenance page

Error and Notification Messageswww.3ware.com 305CauseApplies only to the 9690SA controller.The enclosure temperature is below the enclosure manufactu

Página 244 - Unit Information

Troubleshooting306 3ware SAS/SATA RAID Software User Guide, Version 9.5.1ActionThe temperature sensor should be replaced or repaired. This may require

Página 245 - Drive Information

Error and Notification Messageswww.3ware.com 3078028 Enclosure temp unknownEvent TypeWarning.CauseApplies only to the 9690SA controller.The enclosure

Página 246 - Maintenance Task Buttons

Getting Started with Your 3ware RAID Controller20 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Initial Settings for Policies and Background T

Página 247

Troubleshooting308 3ware SAS/SATA RAID Software User Guide, Version 9.5.1ActionReseat the power supply cord. Replace any failed power supply as soon a

Página 248

Error and Notification Messageswww.3ware.com 309CauseApplies only to the 9690SA controller.There is a power supply in the enclosure, but it is not of

Página 249 - Create Unit

Troubleshooting310 3ware SAS/SATA RAID Software User Guide, Version 9.5.18041 Enclosure voltage overEvent TypeError.CauseApplies only to the 9690SA co

Página 250

Error and Notification Messageswww.3ware.com 311ActionIf applicable, replace the failed power supply.Contact your enclosure manufacturer for more inf

Página 251

Troubleshooting312 3ware SAS/SATA RAID Software User Guide, Version 9.5.1CauseApplies only to the 9690SA controller.The enclosure’s amperage is unknow

Página 252 - Alarms page

313 3ware SAS/SATA RAID Software User Guide, Version 9.5.1AppendicesThe following information is available in the appendices: • Appendix A, “Glossary”

Página 253 - Battery Backup page

314 3ware SAS/SATA RAID Software User Guide, Version 9.5.1AGlossary• 3BM. The 3ware BIOS Manager, used on PC machines. The 3ware BIOS (Basic Input Out

Página 254

www.3ware.com 315• Background rebuild rate. The rate at which a particular controller initializes, rebuilds, and verifies redundant units (RAID 1, RA

Página 255 - Enclosure Summary page

Glossary316 3ware SAS/SATA RAID Software User Guide, Version 9.5.1• Distributed parity. Parity (error correction code) data is distributed across seve

Página 256 - Enclosure Details page

www.3ware.com 317• Hot swapping. The process of removing a disk drive from the system while the power is on. Hot swapping can be used to remove units

Página 257 - Temp Sensor Summary

www.3ware.com 21Background Task Settings(For details, see “Scheduling Background Tasks” on page 173 and “Setting Background Task Rate” on page 172)Ve

Página 258 - Power Supply Summary

Glossary318 3ware SAS/SATA RAID Software User Guide, Version 9.5.1• OCE (Online Capacity Expansion). The process of increasing the size of an existing

Página 259 - 3DM 2 Settings page

www.3ware.com 319• Rebuild task schedule. The specification for when rebuilding, may occur, including start time and duration.•Rebuild a unit. To gen

Página 260 - Password

Glossary320 3ware SAS/SATA RAID Software User Guide, Version 9.5.1• Stripe size. The size of the data written to each disk drive in RAID unit levels t

Página 261 - HTTP Settings

www.3ware.com 321• WWN (World Wide Number). The unique worldwide 64-bit SAS address assigned by the manufacturer to each SAS port and expander device

Página 262 - Troubleshooting

www.3ware.com 322BSoftware InstallationThis appendix provides detailed instructions for installing the 3ware management software for your 3ware RAID

Página 263

Installing Softwarewww.3ware.com 323Installing Software from a Graphical User Interface (GUI)The steps below describe how to install the 3ware RAID m

Página 264 - Command Logging

Software Installation324 3ware SAS/SATA RAID Software User Guide, Version 9.5.15 On the License Agreement page, accept the agreement and click Next.Fi

Página 265 - Available DPM Commands

Installing Softwarewww.3ware.com 325The 3ware Documentation option installs the 3ware HTML Bookshelf on your computer. This is a combined HTML versio

Página 266

Software Installation326 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 118. 3DM 2 Email Configuration Screen9 When a message asks you

Página 267 - Enclosure-Related Problems

Installing Softwarewww.3ware.com 32710 [Optional] On the 3DM 2 Security Configuration screen, specify whether you want to restrict access to localhos

Página 268

www.3ware.com 223First-Time RAID Configuration Using 3BMIf you will install the operating system on and boot from a unit managed through the new 3war

Página 269 - Problems in 3DM and 3BM

Software Installation328 3ware SAS/SATA RAID Software User Guide, Version 9.5.112 If you want the Installation Wizard to connect to 3DM 2 after you fi

Página 270

Installing Softwarewww.3ware.com 32914 When the final installation screen lets you know that installation is complete, click Finish.Figure 124. Fina

Página 271

Software Installation330 3ware SAS/SATA RAID Software User Guide, Version 9.5.1The install file name will be one of the following, depending on your o

Página 272

Installing Softwarewww.3ware.com 331Installing Software on FreeBSD 6.x or 7.x and later from the Command LineThe following steps describe how to inst

Página 273

Software Installation332 3ware SAS/SATA RAID Software User Guide, Version 9.5.1To manually install CLI under FreeBSD 5.x1 Mount the 3ware CD-ROMmount

Página 274

Uninstalling 3ware Softwarewww.3ware.com 333Uninstalling 3ware SoftwareThis section tells you how to uninstall 3ware RAID controller management softw

Página 275

Software Installation334 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Uninstalling 3DM Software on VMwareYou can uninstall CLI, 3DM 2 or the

Página 276 - 0002 Degraded unit

www.3ware.com 335CCompliance and Conformity StatementsThis section is organized into the following topics:• FCC Radio Frequency Interference Statemen

Página 277 - 0004 Rebuild failed

Compliance and Conformity Statements336 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Microsoft Windows Hardware Quality LabAMCC is committed

Página 278 - 0006 Incomplete unit detected

www.3ware.com 337DWarranty, Technical Support, and ServiceThis section is organized into the following topics:• Limited Warranty• Warranty Service an

Página 279 - 0007 Initialize completed

Basic Steps for Creating a Unitwww.3ware.com 23To launch 3BM1 Power up or reboot your system. While the system is starting, watch for a screen simila

Página 280 - 000A Drive error detected

Warranty, Technical Support, and Service338 3ware SAS/SATA RAID Software User Guide, Version 9.5.1parts or replacement products will be provided by AM

Página 281 - 000C Initialize started

AMCC Technical Support and Serviceswww.3ware.com 339Serial ATA RAID Controller, including shipping costs. As soon as practicable thereafter, AMCC wil

Página 282 - 000F SMART threshold exceeded

www.3ware.com 340IndexNumerics2TB support923BMhelp69main screen 63navigation 64screens 63starting 60working in 643DM3DM menus76Alarms page 240Battery

Página 283 - 001A Drive inserted

www.3ware.com 341Drive timeout detected (0009) 268Flash file system error detected (003F) 288Flash file system repaired (0040) 288Incomplete unit det

Página 284 - 001F Unit Operational

342 3ware SAS/SATA RAID Software User Guide, Version 9.5.1bootable unit, specifying 63browser requirements, 3DM 71Buffer ECC error corrected (0039) 28

Página 285 - 0021 Downgrade UDMA mode

www.3ware.com 343status, viewing (3DM) 146statuses 151types 3viewing SMART data 157Drive Details page, 3DM 221Drive ECC error reported (0026) 276Driv

Página 286 - 0023 Sector repair completed

344 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Ggrown defect, definition316Hhardware installation, troubleshooting255help, getting for 3BM

Página 287

www.3ware.com 345RAID 1 7motherboard boot sequence 31motherboard requirements 2Mozilla, setting up 71Multi LUN support (auto-carving) 88, 92multiple

Página 288 - 0026 Drive ECC error reported

346 3ware SAS/SATA RAID Software User Guide, Version 9.5.13DM 233definition 319removing a unit 235definition 319Replacement drive capacity too small (

Página 289 - 0029 Verify started

www.3ware.com 347UUDMA mode, definition320ultra DMA protocol 273Unclean shutdown detected (0008) 267unconfigured disks, exporting 96unconfigured driv

Página 290 - 002A Verify failed

First-Time RAID Configuration Using 3BM24 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 10. 3ware Controller Board Selection ScreenYou

Página 291 - 002B Verify completed

348 3ware SAS/SATA RAID Software User Guide, Version 9.5.1disable on degrade, part of Storsave profile 125enabling in 3BM 119enabling in 3DM 118write

Página 293 - 0030 Drive not supported

Basic Steps for Creating a Unitwww.3ware.com 253 Make sure that the proper drives are listed.Figure 12. Create Disk Array DisplayTo name the unit an

Página 294 - 0034 Migration failed

First-Time RAID Configuration Using 3BM26 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 14. Stripe Sizes for a RAID 5To set other poli

Página 295 - 0035 Migration completed

Basic Steps for Creating a Unitwww.3ware.com 27 1 Use the arrow keys or press Tab to move to the Boot Volume Siz

Página 296 - 0038 SO-DIMM not detected

iv 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Installing the driver when your primary storage will be managed by the 3ware RAID controller

Página 297

First-Time RAID Configuration Using 3BM28 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 15. Summary of Volumes to be CreatedTo finish

Página 298 - 003C Initialize paused

Basic Steps for Creating a Unitwww.3ware.com 294Type Y to continue, delete any existing data on the drives, and create the unit.If you chose foregrou

Página 299 - 003E Migration paused

First-Time RAID Configuration Using 3BM30 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Specifying a Hot SpareYou can designate one of the Ava

Página 300

Making Drives Visible to the Operating Systemwww.3ware.com 31Making Drives Visible to the Operating SystemBy default, if you leave individual drives

Página 301

www.3ware.com 324 Driver InstallationThis chapter provides details about how to install the driver for your 3ware RAID controller and make the units

Página 302 - 0046 Battery voltage is high

Driver Installation Under Windowswww.3ware.com 33Driver Installation Under Windows The 3ware RAID controller can

Página 303

Driver Installation34 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Creating a 3ware Driver DisketteIf you are installing Windows on a new uni

Página 304

Driver Installation Under Windowswww.3ware.com 354 When a box with AMCC 3ware 9000 Series RAID Controller appears, press Enter to select it.5Type S i

Página 305

Driver Installation36 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Installing the 3ware Driver on a Windows System that Boots from a Differen

Página 306

Driver Installation Under Windowswww.3ware.com 37Figure 18. 3ware Device Driver Installation Wizard3 Click Next.Depending upon your operating system

Página 307

www.3ware.com vSetting Unit Policies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116Enabling an

Página 308 - 0055 Battery charging started

Driver Installation38 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 20. Windows XP Final Install Screen

Página 309 - 0057 Battery charging fault

Driver Installation Under Windowswww.3ware.com 39To install the 3ware driver under Windows with the Found New Hardware wizard1 Click the Next button

Página 310 - 005B Battery is not present

Driver Installation40 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 23. Welcome to the Found New Hardware Wizard7 When the second Comp

Página 311 - 005C Battery is weak

Driver Installation Under Windowswww.3ware.com 41Making Units Managed by a 3ware Controller Available to WindowsAfter the 3ware driver has been insta

Página 312 - 0063 Enclosure added

Driver Installation42 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Driver Installation Under Linux A dri

Página 313 - 8001 Enclosure fan error

Driver Installation Under Linuxwww.3ware.com 43Obtaining 3ware Linux DriversObtain the 3ware driver for Linux from one of these two sources: •3ware s

Página 314 - 8004 Enclosure fan unknown

Driver Installation44 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Driver Installation Under Red Hat Linux or Fedora CoreMaterials required•

Página 315 - 8020 Enclosure temp normal

Driver Installation Under Linuxwww.3ware.com 45Installing the 3ware Kernel Driver Module while Installing Red Hat Linux on a New Unit

Página 316 - 8022 Enclosure temp high

Driver Installation46 3ware SAS/SATA RAID Software User Guide, Version 9.5.1 8 Click reboot button to finish inst

Página 317 - 8025 Enclosure temp removed

Driver Installation Under Linuxwww.3ware.com 47• For a i586 kernel, the kernel string will end in 586. For example: 2.6.16-586• For a PAE kernel (Phy

Página 318 - 8027 Enclosure temp critical

vi 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Chapter 10. Maintaining Your Controller. . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 319 - 8031 Enclosure power fail

Driver Installation48 3ware SAS/SATA RAID Software User Guide, Version 9.5.1For Fedora Core on AMD Opteron and Intel EM64T, type:cp /mnt/packages/driv

Página 320 - 8034 Enclosure power unknown

Driver Installation Under Linuxwww.3ware.com 49For Fedora Core on Intel x86 and AMD x86, type: cp /mnt/packages/drivers/linux/fedora/<version>/

Página 321 - 8040 Enclosure voltage normal

Driver Installation50 3ware SAS/SATA RAID Software User Guide, Version 9.5.1You can load the driver from a floppy diskette on which you have installed

Página 322 - 8042 Enclosure voltage under

Driver Installation Under Linuxwww.3ware.com 51Installing the 3ware Kernel Driver Module on a SuSE Linux System that Boots from a Different Device1 L

Página 323 - 8045 Enclosure current over

Driver Installation52 3ware SAS/SATA RAID Software User Guide, Version 9.5.1For openSuSE and SuSE Linux Enterprise Server 64-bit (x86_64), type:cp /mn

Página 324

Driver Installation Under FreeBSDwww.3ware.com 53Driver Installation Under FreeBSD This section provides details

Página 325 - Appendices

Driver Installation54 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Driver source files for FreeBSD 5.x, 6.x, and 7.x, located at: •FreeBSD 5.

Página 326 - Glossary

Driver Installation Under FreeBSDwww.3ware.com 55Installing the Kernel Driver Module while Installing FreeBSD on a Unit Managed by a 3ware RAID Contr

Página 327

Driver Installation56 3ware SAS/SATA RAID Software User Guide, Version 9.5.111 At the loader prompt, load twa.ko from the floppy using "load disk

Página 328

Driver Installation Under VMware ESX 3.x Serverwww.3ware.com 57Driver Installation Under VMware ESX 3.x ServerThis section provides details about how

Página 329

www.3ware.com viiError and Notification Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258Error and Notificat

Página 330

Driver Installation58 3ware SAS/SATA RAID Software User Guide, Version 9.5.16 When prompted, choose your keyboard type and press Enter.7 At the “Updat

Página 331

Driver Installation Under VMware ESX 3.x Serverwww.3ware.com 598 Unmount the CD.cd /umount /mnt/cdromand remove the CD from the drive.9 Reboot the se

Página 332

www.3ware.com 6053ware BIOS Manager (3BM) IntroductionThis section describes the basics of using 3ware BIOS Manager (3BM), one of the tools you can u

Página 333

Starting 3BMwww.3ware.com 613 Press Alt-3 immediately to bring up the 3ware BIOS Manager (3BM). Normally your 3ware configuration remains on-screen f

Página 334 - Software Installation

3ware BIOS Manager (3BM) Introduction62 3ware SAS/SATA RAID Software User Guide, Version 9.5.1You see a screen similar to the warning message below, w

Página 335 - /mnt/autorun

Working in the 3BM Screenswww.3ware.com 63 Working in the 3BM ScreensThe main 3BM screen (Figure 29) shows the c

Página 336

3ware BIOS Manager (3BM) Introduction64 3ware SAS/SATA RAID Software User Guide, Version 9.5.1• Incomplete Drives and Others lists drives that are rem

Página 337

Working in the 3BM Screenswww.3ware.com 65Highlight one of the primary buttons on the main screen:• Create Unit• Delete Unit• Maintain Unit• Settings

Página 338

3ware BIOS Manager (3BM) Introduction66 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Adjusting BIOS Option Settings3BM includes a few setting

Página 339 - Next to continue

Adjusting BIOS Option Settingswww.3ware.com 67BIOS Loading OptionsLoad Control. This setting is enabled by default. It allows you to boot from RAID u

Página 340

viii 3ware SAS/SATA RAID Software User Guide, Version 9.5.1

Página 341 - /packages/installer/linux/x86

3ware BIOS Manager (3BM) Introduction68 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Displaying Information About the Controller and Related

Página 342

Getting Help While Using 3BMwww.3ware.com 69Getting Help While Using 3BMYou can get help with using 3BM while you are in the BIOS manager. • Press F1

Página 343

70 3ware SAS/SATA RAID Software User Guide, Version 9.5.163DM 2 (3ware Disk Manager) Introduction 3ware Disk Mana

Página 344

Browser Requirements for 3DMwww.3ware.com 71Browser Requirements for 3DM3DM runs in most current web browsers. Tested and supported browsers include:

Página 345 - Uninstalling 3ware Software

3DM 2 (3ware Disk Manager) Introduction72 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Installing 3DM3DM 2 can be installed from the 3ware CD

Página 346

Starting 3DM and Logging Inwww.3ware.com 73To log in to the 3DM web application1 Open your browser and enter the URL for your system. The default URL

Página 347 - Statements

3DM 2 (3ware Disk Manager) Introduction74 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Managing the 3DM 2 Daemon under Linux, VMware, and Fre

Página 348

Working with the 3DM Screenswww.3ware.com 75Viewing 3DM Remotely Using a Web BrowserWhen remote administration is enabled on the 3DM 2 Settings page,

Página 349 - Warranty, Technical Support

3DM 2 (3ware Disk Manager) Introduction76 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Figure 33. 3DM Main Screen

Página 350 - State Law Provisions

Working with the 3DM Screenswww.3ware.com 77The Management menu gives you access to tasks used for managing controller-level settings (background tas

Página 351 - Feedback on this manual

ix 3ware SAS/SATA RAID Software User Guide, Version 9.5.1About this User GuideThis document, 3ware SAS/SATA RAID Software User Guide, Version 9.5.1, p

Página 352

3DM 2 (3ware Disk Manager) Introduction78 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Viewing Information About Different ControllersIf you

Página 353

Working with the 3DM Screenswww.3ware.com 793DM Screens and What They're Used For The table below shows a list of the pages you work with in 3DM

Página 354

3DM 2 (3ware Disk Manager) Introduction80 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Controller Phy Summary pageShows the properties of con

Página 355

Setting Up 3DM Preferenceswww.3ware.com 81Setting Up 3DM PreferencesThe 3DM 2 Settings page lets you define preference settings that affect the overa

Página 356

3DM 2 (3ware Disk Manager) Introduction82 3ware SAS/SATA RAID Software User Guide, Version 9.5.1To set or change the password1 Click 3DM 2 Settings on

Página 357

Setting Up 3DM Preferenceswww.3ware.com 83To set up event notification1 Click 3DM 2 Settings on the menu bar.2In the E-mail Notification section of t

Página 358

3DM 2 (3ware Disk Manager) Introduction84 3ware SAS/SATA RAID Software User Guide, Version 9.5.1Enabling and Disabling Remote AccessWhen remote access

Página 359

Setting Up 3DM Preferenceswww.3ware.com 85Setting the Frequency of Page RefreshesSince the status of the drives attached to your 3ware RAID controlle

Página 360

86 3ware SAS/SATA RAID Software User Guide, Version 9.5.17Configuring Your ControllerThis section describes how to view details about the controller,

Página 361

Viewing Information About a Controllerwww.3ware.com 87Figure 36. Controller Summary Page 2 To see more details

Comentários a estes Manuais

Sem comentários